Technical Paper
Bottom Chord Dead Load TF No. 1010
Thursday, April 3, 2025 SBCA Knowledge Center I have built a 30 ft. x 40 ft. pole barn with nine 30 ft. 2x4 7/12 pitch trusses that are 5 ft. O.C. I am planning to finish out the interior and will attach 7/16 x 4 x 8 OSB sheets to the trusses for my ceiling.
Technical Paper
Uplift Values on Truss Design Drawings TF No. 1013
Thursday, April 3, 2025 SBCA Knowledge Center I am a building inspector and I have a question on information provided on truss design drawings. What does the uplift reaction number represent?
Technical Paper
Snow Load TF No. 1015
Thursday, April 3, 2025 SBCA Knowledge Center I am a truss manufacturer in an area of the country that often has some pretty severe winters. What are some of the things that need to be considered when designing for snow loads?
Technical Paper
Design Loads vs Typical Loading Conditions TF No. 1016
Thursday, April 3, 2025 SBCA Knowledge Center The Corps' guide spec for wood construction requires the drawings to indicate the design forces on each truss member for the worst loading condition.
Technical Paper
Post Fire Retardant Treatment TF No. 1027
Thursday, April 3, 2025 SBCA Knowledge Center Is a Class A fire rating (provided by our liquid spray-on fire retardant) acceptable in certain situations?
Technical Paper
Scissors Truss Diagonal Bracing TF No. 1042
Thursday, April 3, 2025 SBCA Knowledge Center We are finding it difficult to design permanent diagonal bracing for scissors trusses. The truss is often only a few feet in depth, which does not provide adequate room for diagonal bracing.
Technical Paper
Temporary Bracing Documents TF No. 1049
Thursday, April 3, 2025 SBCA Knowledge Center Is it common practice for the supplier/distributor of a truss to provide a publication regarding temporary bracing with the delivery of the material?
Technical Paper
Moisture Content Equilibrium and Truss Movement TF No. 1057
Thursday, April 3, 2025 SBCA Knowledge Center How long does it take the moisture content to stabilize in a wood truss? I live in southern California. Also, how much deflection should be expected in a scissors truss over a partition wall?
Technical Paper
Metal Connector Plates Peeling TF No. 1066
Thursday, April 3, 2025 SBCA Knowledge Center I am investigating a roof failure in a 22-year-old structure. The connector plates have peeled open like a banana skin in several instances. The teeth do not appear sheared or torn at the wood surface.
Technical Paper
Truss Uplift TF No. 1074
Thursday, April 3, 2025 SBCA Knowledge Center What is truss uplift?
Technical Paper
Transforming Attic into Living Space TF No. 1076
Thursday, April 3, 2025 SBCA Knowledge Center We are looking into developing the attic space above our garage into a media room. The garage is attached to the home and we would enter this area from the living room.
Technical Paper
Deck Ledger Boards TF No. 1078
Thursday, April 3, 2025 SBCA Knowledge Center Is it possible to attach deck ledger boards to the ends of floor trusses? If not, are there any modifications that would make this possible?